BYHQB - Y24 W 538 UNDERCOATER WEATHER PERFECT
- MSDS: BYHQB
- Manufacturer: SHERWIN WILLIAMS CO MARTIN SENOUR CO
- Product Name: Y24 W 538 UNDERCOATER WEATHER PERFECT
- National Stock Number: 8010-00F006390
Product Identification
Product ID:Y24 W 538 UNDERCOATER WEATHER PERFECT
MSDS Date:03/01/1991
FSC:8010
NIIN:00F006390
MSDS Number: BYHQB
Responsible Party
CLEVELAND, OH 44115-1042
US
Emergency Phone: 216-566-2917/216-566-2902
Info Phone: 216-566-2902/216-566-2917
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
ETHYLENE GLYCOL, GLYCOL *96-1*
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: <5%
OSHA PEL 50 PPM
ACGIH TLV: C 127 MG/CUM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
KEROSENE (PETROLEUM), HYDROTREATED (C10-C15 SATURATED
CAS: 64742-47-8
RTECS: OA5504000
MEDIUM ALIPHATIC NAPHTHA (AROMATIC 100), PARAFFIN-NAPTHANES
CAS: 64742-88-7
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
TALC (POWDER), (ASBESTOS FREE), TALCUM; HYDROUS MAGNESIUM
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: 37%
OSHA PEL 2 MG/CUM (RESP DUST)
ACGIH TLV: 2 MG/CUM (RESP DUST)
TITANIUM DIOXIDE, TIO2 (SUSPECTED ANIMAL CARCINOGEN, IARC
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 8.73%
OSHA PEL 15 MG/CUM
ACGIH TLV: 10 MG/CUM (DUST)
2.9 LBS/GAL
RTECS: 9999999VO
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE IRRITATION OF EYES, SKIN &
RESPIRATORY SYSTEM, NERVOUS SYSTEM DEPRESSION & POSSIBLY DEATH.
CHRYSTALLINE SILICA: LONG TERM EXPOSURE TO HIGH LEVELS OF SILICA
DUST, WHICH CAN OCCUR ONLY WHEN SA NDING/ABRADING THE DRY FILM, MAY
CAUSE LUNG DAMAGE (SILICOSIS) & POSSIBLY CANCER. (SEE SUPP)
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, UNCONSIOUSNESS, HEADACHE,
DIZZINESS, NAUSEA, LOSS OF COORDINATION, REDNESS, ITCHING, BURNING
SENSATION.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. KEEP WARM
& QUIET. SKIN: WASH AREA THOROUGHLY W/SOAP & WATER. EYES: FLUSH
W/LARGE AMOUNTS OF WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN
ALL CASE S.
Fire Fighting
Flash Point Method:PMCC
Flash Point:102-105F
Lower Limits:0.9
Upper Limits:6
Extinguishing Media:CO2, DRY CHEMICAL, FOAM
Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT & SCBA. WATER
SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE
PREFERABLE. WATER MAY BE USED TO COOL CLOSED CONTAINERS
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATIONS TO HOT SURFACES REQUIRES
SPECIAL PRECAUTIONS.
Accidental Release
Spill Release Procedures:REMOVE SOURCES OF IGNITION. VENTILATE & REMOVE
W/INERT ABSORBENT.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT & OPEN FLAME. USE
APPROVED BONDING & GROUNDING PROCEDURES. KEEP CONTAINER CLOSED WHEN
NOT IN USE. USE ONLY W/ADEQUATE VENTILATION.
Other Precautions:DON'T TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
TRNSFER ONLY TO APPROVED CONTAINERS W/COMPLETE & APPROPRIATE
LABELING. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING &
INHALING THE CONTENTS CA N BE HARMFUL/FATAL.
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOSURE CAN'T BE CONTROLLED <
APPLICABLE LIMITS, WEAR A NIOSH/MSHA APPROVED PROPERLY FITTED
ORGANIC VAPOR/PARTICULATE RESPIRATOR. WHEN SANDING/ABRADING DRIED
FILM, WEAR A DUST/MIST RESPIR ATOR APPROVED BY NIOSH/MSHA.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE TO
MAINTAIN EXPOSURE BELOW APPLICABLE EXPOSURE LIMITS.
Protective Gloves:REQUIRED
Eye Protection:SAFETY GLASSES W/UNPERFORATED SIDESHIELD
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH HANDS AFTER USING.
Supplemental Safety and Health
HEALTH HAZARDS: PROLONGED OVEREXPOSURE TO SOLVENTS MAY CAUSE ADVERSE
EFFECTS TO THE LIVER & URINARY SYSTEMS. REPEATED/PROLONGED
OVEREXPOSURE TO SOLVENTS MAY CAUSE PERMANENT BRAIN & NERVOUS SYSTEM
DAMA GE. KEEP CONTAINERS TIGHTLY CLOSED. AVOID CONTACT W/SKIN &
EYES.
Chemical Properties
Boiling Pt:B.P. Text:300-448F
Vapor Density:>1
Spec Gravity:0.92-1.54
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:32-65
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, OPEN FLAME, ELECTRICAL EQUIPMENT,
SPARKS & OTHER IGNITION SOURCES.
Hazardous Decomposition Products:BY FIRE: CO2, CO
Disposal
Waste Disposal Methods:PRODUCT WASTE MAY BE HAZARDOUS UNDER RCRA & MUST
BE TESTED FOR IGNITIBILITY TO DETERMINE THE APPLICABLE EPA
HAZARDOUS WASTE NUMBERS. INCINERATE IN APPROVED FACILITY. DON'T
INCINERATE CLOSED CONTAINER. DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.